Products - Overly Door Company
Model LRB-P
Recommended Hardware
Closers |
Exit Devices |
Flush-Bolts |
Hinges |
Locks |
All |
None
Surface Mounted Closer
ANSI 156.4 Grade 1
Click Here for Suggested Models:
Corbin/Russwin DC2000, DC3000, DC4000
Dorma 640, 540, 7600, 7800, TS83
LCN 4010, 4020, 4041 Super Smoothie
Norton 7500, 8500
Sargent 250, 251, 350, 351, 1230, 1231, 1250, 1251
Mortise Exit Device
Modified latch-bolt, strike plate, and scalp plate
Click Here for Suggested Models:
Sargent 8300
Corbin/Russwin ED6600
Von Duprin 9875/9975
6-3/4" x 1" Flush-Bolt
Modified flush-bolt pin provided by Overly
ANSI 156.16
Click Here for Suggested Models:
5" x 4-1/2" Heavy Weight Hinge
ANSI A5111 or A8111
Click Here for Suggested Models:
Hager BB1168
Hager BB1199
McKinney T4A3786
McKinney T4A3386
Stanley FBB168
Stanley FBB199
Mortise Lock
Modified latch-bolt, strike plate, and scalp plate
ANSI A156.13 Series 1000 Grade 1
Click Here for Suggested Models:
Best 35H
Sargent 8200
Schlage "L" Series
Corbin/Russwin ML2000
Quick Specs
Maximum Fire Rating: A
Conventional Profiles
This door assembly uses a standard Hollow Metal profile. This ensures it will fit seamlessly into your facility, whether for a mechanical room or a board room.
Hospital
Stops
Hospital stops are available for medical applications, or anywhere cleanliness
is a concern. The hospital stop allows a mop or broom to be used unobstructed
by the frame stop. You may also want to consider using hospital tip hinges as
well.
UL Fire Ratings
Overly has successfully tested many of its products to the latest UL fire
test standards, including UL 10B (neutral pressure), UL10C/UBC 7-2 (positive pressure).
We provide all fire labeling under Underwriter's
Laboratories procedures. Metal doors are available with up to 3 hour fire ratings.
Tested and certified in accordance with UL 10C and UBC 7-2 for doors and UBC 7-4
for windows.